Specifications CS 101
FUNCTION
The device measures the input
sinusoidal current; (form factor 1,11).
Fig.1 shows the relation between the
input current and the outputs (voltage,
current).
REMARK:
it replaces CS 01 changing the wirings
(See Tab. A)
Features CS 101
INPUT
pin 9-10 with built-in current
transformer.
Permanent overload: 200%.
OUTPUTS: (max error 1%).
Current: 4-20mA/0-20mA on request500W max - pin 5-6 (current outgoing
from pin 6).
Voltage: 0-10Vdc - pin 7-4 (+on pin 7)
load higher than 10kW.
VISUALIZATIONS
ON GREEN LED: supply on.
GALVANIC SEPARATION
Ensured by built-in current transformer.
STEP RESPONSE:
(10÷90%)< 100 ms
INSTALLATION: see fig. 2.
(Wiring to an electrical board with a
differential relay and a sectionalizing
switch).
The length of every wiring must be less
than 30m.
SUPPLY: 2VA - 50-60Hz
Tolerance: ± 15%
Pin 2-11: 230 Vac, 115 Vac or 24 Vac.
(24 Vdc on request).
SIZE: 48x96x90 mm
undecal male base.
Accessories available on request:
E 171: hooks for flush mounting.
E 172: undecal female base for DIN.
M 13A: plexiglas protection IP 54-tight
closure (for flush mounting).
E 346: spring protecting from
vibrations.
Template: 45x92 mm.
WEIGHT: 0,300 kg COLOUR: black
WORKING TEMPERATURE: 0÷70°C