We are not the manufacturer, authorised distributor or authorised representative of the Euchner brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
Euchner
Country
Germany
Name
CTP-L1-AR-U-HA-AZ-SAB-122812
Part number
122812
Description
Sicherheitsschalter mit Sicherheitsschloss CTP-L1-AR-U-HA-AZ-SAB-122812
Stock availability:
On request
If you need to buy Euchner CTP-L1-AR-U-HA-AZ-SAB-122812 122812 with quick shipment anywhere in the planet, Canada, United States, Mexico, Belize, Brazil, Austria, Thailand, Qatar, Mongolia, Croatia, Equatorial Guinea, Ghana, Nepal, Indonesia, Hungary, Colombia, Niger, Lithuania, Latvia, The Bahamas, Zambia, Serbia, Togo, Antigua and Barbuda, Afghanistan, Bangladesh, Kenya, Brunei, Costa Rica, Senegal, Malta, Pakistan, Myanmar, Morocco, Peru, Czech Republic, Jordan, Australia, France, Sri Lanka, Poland, South Korea, Rwanda, Ireland, Kiribati, South Africa, Uganda, Djibouti then turn your attention to FAMAGA.
For more than 10 years, FAMAGA has not only provided customers with superior quality equipment Euchner, but also has a perfectly established logistics system. You can be confident that the order will show up anywhere in the world as soon as possible. The consumer doesn’t risk waste money on unsuitable goods, thanks to the qualified specialists, who will learn all the details of the problem and help make the finest option.
You get a devoted companion for a long time through cooperating with FAMAGA. Our team are always ready to offer the most supportive terms of purchase Euchner CTP-L1-AR-U-HA-AZ-SAB-122812 122812 for those who decide to become a steady buyer of the company. We are interested in setting up long-term and mutually effective partnership with each client. Consequently, through cooperating with us, you get top class items from prominent manufacturers of industrial machinery at the best price, with a guarantee from the manufacturer, moreover full acquiescence with lawmaking and certification rules during delivery.
To get accurate information on questions of interest, call us. FAMAGA experts will be delighted to help. If you have a massive order, then a list of the necessary machinery can be sent by e-mail [email protected].
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | FI1B | Enable input for channel 2 | WH | |
X 1.2 | UB | Operating voltage of AR electronics 24 V DC | BN | |
X 1.3 | FO1A | Safety output, channel 1 | GN | |
X 1.4 | FO1B | Safety output, channel 2 | YE | |
X 1.5 | OL | Guard locking monitoring output | GY | |
X 1.6 | FI1A | Enable input for channel 1 | PK | |
X 1.7 | 0 V UB | Operating voltage of AR electronics 0 V | BU | |
X 1.8 | RST | Reset input | RD | |
X 2.1 | IMM | Operating voltage of guard locking solenoid 0 V | BN | |
X 2.2 | OD | Door monitoring output | WH | |
X 2.3 | OI | Diagnostic output | BU | |
X 2.4 | IMP | Operating voltage of guard locking solenoid 24 V DC | BK | |
X 2.5 | - | n.c. | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | 8 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.140 ms |
Test pulses | max.1,0 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 2 A |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Risk time according to EN 60947-5-3 | |
Delay per device | 5 ms |
Single device | max.260 ms |
Switching load | |
According to UL | 24V DC, class 2 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
High U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
Low U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OL | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |