IFM SI5010
  IFM SI5010

We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.

IFM SI5010

Manufacturer

IFM

Country

Germany

Part number

SI5010

Description

Flow monitor with LED bar graph for indication of switch point and flow

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications SI5010

Reliable monitoring of liquids and gases in pipes. Variable process connection using adapters. Easy setting of the switch points for quick set-up. Robust stainless steel housing for use in harsh industrial environments.

Features SI5010

Application
MediaLiquids, Gases
Measured medium temperature [°C]-25…80
Pressure strength [bar]300
MAWP (for use according to CRN) [bar]208
Liquid media
Measured medium temperature [°C]-25…80
Gases
Measured medium temperature [°C]-25…80
Electronic data
Operating voltage [V]18…36 DC
Current consumption [mA] <60
Protection classIII
Reverse polarity protection yes
Power-on delay time [s]10
Inputs/outputs
Number of inputs and outputsNumber of digital outputs: 1
Outputs
Total number of exits1
Output signalSwitching signal, IO-Link, (configurable)
Electrical versionPNP
Number of digital outputs1
Output signal functionnormally open / normally closed, (parameterizable)
Max. voltage drop of switching output DC [V]2.5
DC load current of switching output DC [mA]250
Short-circuit protectionyes
Short-circuit protection typeclocked
Overcurrent protectionyes
Measurement/setting range
Liquid media
Parameter setting within [cm/s]3…300
Max. sensitivity [cm/s]3…100
Gases
Parameter setting within [cm/s]200…3000
Max. sensitivity [cm/s]200…800
Accuracy/accuracy
Reproducibility [cm /s]1…5
Note about repeatability
for water 5…100 cm/s, 25 °C
Factory setting
Temperature drift [cm/s x 1/K]0.1, (for water 5…100 cm/s, 10…70 °C)
Max. temperature gradient (rate of change of medium temperature) [K/min]300
Switch point error [cm/ s]± 2…± 10, (for water 5…100 cm/s, 25 °C, factory setting)
Hysteresis [cm/ s]2…5, (for water 5…100 cm/s, 25 °C, factory setting)
Response time
Liquids
Response time [s]1…2, (for temperature gradient: 1 K/min)
Gases
Response time [s]1 …10
Software / Programs programming
Setting the switching pointProgramming buttons
Interfaces
Communication interfaceIO-Link
Transmission methodCOM2 (38.4 kBaud)
IO-Link test1.1
SDCI standardIEC 61131- 9
IO-Link device ID54 d / 00 00 36 h
ProfilesSmart Sensor: Process Data Variable, Device Identification
SIO modeyes
Desired port typeA
Analog operating data2
Binary operating data2
Minimum operating cycle time [ms]3
Operating conditions
Ambient temperature [°C]-25…80
Storage temperature [°C]-25…100
Degree of protectionIP 65, IP 67
Tests / approvals
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Impact resistance
DIN IEC 60068-2-2750 g (11 ms)
Vibration resistance
DIN EN 60068-2-620 g ( 55…2000 Hz)
MTTF [years]298
Mechanical data
Weight [g]234.8
Dimensions [mm]M18 x 1.5
Thread designationM18 x 1.5
Materialstainless steel steel (1.4404 / 316L), stainless steel steel (1.4301/304), PC, PBT-GF20, EPDM/X mediumstainless steel steel (1.4404 / 316L), O-ring: FKM 80 Shore A
Process connectionM18 x 1.5 internal thread
Displays / Controls
Display
Function10 x LED, 3-color
Notes
Packing quantity1 piece
Electrical connection
ConnectionConnector: 1 x M12