We are not the manufacturer, authorised distributor or authorised representative of the IFM brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.
Manufacturer
IFM
Country
Germany
Part number
SI5010
Description
Flow monitor with LED bar graph for indication of switch point and flow
Stock availability:
On request
Application | |||||
---|---|---|---|---|---|
Media | Liquids, Gases | ||||
Measured medium temperature [°C] | -25…80 | ||||
Pressure strength [bar] | 300 | ||||
MAWP (for use according to CRN) [bar] | 208 | ||||
Liquid media | |||||
Measured medium temperature [°C] | -25…80 | ||||
Gases | |||||
Measured medium temperature [°C] | -25…80 | ||||
Electronic data | |||||
Operating voltage [V] | 18…36 DC | ||||
Current consumption [mA] | <60 | ||||
Protection class | III | ||||
Reverse polarity protection | yes | ||||
Power-on delay time [s] | 10 | ||||
Inputs/outputs | |||||
Number of inputs and outputs | Number of digital outputs: 1 | ||||
Outputs | |||||
Total number of exits | 1 | Output signal | Switching signal, IO-Link, (configurable) | ||
Electrical version | PNP | ||||
Number of digital outputs | 1 | ||||
Output signal function | normally open / normally closed, (parameterizable) | ||||
Max. voltage drop of switching output DC [V] | 2.5 | ||||
DC load current of switching output DC [mA] | 250 | ||||
Short-circuit protection | yes | ||||
Short-circuit protection type | clocked | ||||
Overcurrent protection | yes | ||||
Measurement/setting range | |||||
Liquid media | |||||
Parameter setting within [cm/s] | 3…300 | ||||
Max. sensitivity [cm/s] | 3…100 | ||||
Gases | |||||
Parameter setting within [cm/s] | 200…3000 | ||||
Max. sensitivity [cm/s] | 200…800 | ||||
Accuracy/accuracy | |||||
Reproducibility [cm /s] | 1…5 | ||||
Note about repeatability |
| ||||
Temperature drift [cm/s x 1/K] | 0.1, (for water 5…100 cm/s, 10…70 °C) | ||||
Max. temperature gradient (rate of change of medium temperature) [K/min] | 300 | ||||
Switch point error [cm/ s] | ± 2…± 10, (for water 5…100 cm/s, 25 °C, factory setting) | ||||
Hysteresis [cm/ s] | 2…5, (for water 5…100 cm/s, 25 °C, factory setting) | ||||
Response time | |||||
Liquids | |||||
Response time [s] | 1…2, (for temperature gradient: 1 K/min) | ||||
Gases | |||||
Response time [s] | 1 …10 | ||||
Software / Programs programming | |||||
Setting the switching point | Programming buttons | ||||
Interfaces | |||||
Communication interface | IO-Link | ||||
Transmission method | COM2 (38.4 kBaud) | ||||
IO-Link test | 1.1 | ||||
SDCI standard | IEC 61131- 9 | ||||
IO-Link device ID | 54 d / 00 00 36 h | ||||
Profiles | Smart Sensor: Process Data Variable, Device Identification | ||||
SIO mode | yes | ||||
Desired port type | A | ||||
Analog operating data | 2 | ||||
Binary operating data | 2 | ||||
Minimum operating cycle time [ms] | 3 | ||||
Operating conditions | |||||
Ambient temperature [°C] | -25…80 | ||||
Storage temperature [°C] | -25…100 | ||||
Degree of protection | IP 65, IP 67 | ||||
Tests / approvals | |||||
EMC |
| ||||
Impact resistance |
| ||||
Vibration resistance |
| ||||
MTTF [years] | 298 | ||||
Mechanical data | |||||
Weight [g] | 234.8 | ||||
Dimensions [mm] | M18 x 1.5 | ||||
Thread designation | M18 x 1.5 | ||||
Material | stainless steel steel (1.4404 / 316L), stainless steel steel (1.4301/304), PC, PBT-GF20, EPDM/X medium | stainless steel steel (1.4404 / 316L), O-ring: FKM 80 Shore A | |||
Process connection | M18 x 1.5 internal thread | ||||
Displays / Controls | |||||
Display |
| ||||
Notes | |||||
Packing quantity | 1 piece | ||||
Electrical connection | |||||
Connection | Connector: 1 x M12 |