We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to receive Keyence GL-R63F with quick shipment anywhere in the earth, Canada, United States, Mexico, Iran, Ghana, Argentina, Dominica, Ecuador, Bulgaria, Togo, Rwanda, Switzerland, Grenada, Bosnia and Herzegovina, Montenegro, Brazil, Turkey, Malawi, The Bahamas, Kiribati, Denmark, Latvia, Ethiopia, Saudi Arabia, Algeria, South Africa, Qatar, Comoros, Burkina Faso, Tajikistan, Oman, Turkmenistan, Suriname, Zimbabwe, Afghanistan, Namibia, Morocco, Eswatini, Czech Republic, Japan, Chile, Côte d\'Ivoire, Bolivia, South Sudan, Costa Rica, Canada, France then turn your attention to FAMAGA.
For more than 10 years, FAMAGA has not particularly provided customers with superior quality equipment Keyence, but also has a perfectly established logistics chain. You can be confident that the order will turn up anywhere in the earth as soon as possible. The consumer doesn’t risk paying money on inadequate,unfit goods, thanks to the proficient professionals, who will review all the details of the problem and help make the finest option.
You get a faithful teammate for a long time through collaborating with FAMAGA. Our team members are always ready to give the most supportive terms of purchase Keyence GL-R63F for those who decide to become a steady buyer of the company. We are open,attracted in setting up long-term and mutually productive collaboration with each customer. Consequently, through collaborating with us, you get superior quality equipment from prominent manufacturers of industrial materials at the acceptable charges, with a guarantee from the manufacturer, moreover full acquiescence with regulation and certification rules during delivery.
To get exact information on questions of interest, connect with us. FAMAGA experts will be delighted to assist. If you have a massive order, then a list of the requested materials can be sent by e-mail [email protected].
Model | GL-R63F | ||
Detection capability | o14 mm | ||
Beam axis spacing/Lens diameter | 10 mm / o4 | ||
Detecting distance | 0.2 to 10 m*1 | ||
Effective aperture angle | Max. ±2.5° (When operating distance is 3 m or more) | ||
Light source | Infrared LED (870 nm) | ||
Response time (OSSD) (ms) | Wire synchronisation, One-line or Optical synchronisation system (Channel 0) | ON>OFF | 11.2 |
OFF>ON | 55.6*2 | ||
All blocked>ON | 81.7*3 | ||
Optical synchronisation system (Channel A or B) | ON>OFF | 16.3 | |
OFF>ON | 63.2*2 | ||
All blocked>ON | 101.8*3 | ||
Detection mode | Turns on when no interruptions are present in the detection zone | ||
Synchronisation between the transmitter and receiver | Optical synchronisation or Wire synchronisation (Determined by wiring) | ||
Light interference prevention function | Prevents mutual interference in up to two GL-R systems. Optical synchronization: prevented by Channel A and B with setting switch Wire synchronization: prevented automatically | ||
Control output (OSSD output) | Output | 2 transistor outputs. (PNP or NPN is determined by the cable type) | |
Max. load current | 500 mA*4 | ||
Residual voltage (during ON) | Max. 2.5 V (with a cable length of 5 m) | ||
OFF state voltage | Max. 2.0 V (with a cable length of 5 m) | ||
Leakage current | Max. 200 µA | ||
Max. capacitive load | 2.2 µF | ||
Load wiring resistance | Max. 2.5 ? | ||
Supplemental output (Non-safety-related output) | AUX | transistor outputs. (PNP or NPN is determined by the cable type) Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 5 m) | |
Error output | |||
Muting lamp output | Incandescent lamp (24 VDC, 1 to 5.5 W) LED lamp (load current: 10 to 230 mA) can be connected. | ||
External input | When using a PNP output cable | EDM input Wait input Reset input Muting input 1, 2 Override input | ON voltage: 10 to 30 V OFF voltage: Open or 0 to 3 V Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) |
When using an NPN output cable | ON voltage: 0 to 3 V OFF voltage: Open or 10 V or more Up to the power voltage Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only) | ||
Rating | Power voltage | 24 VDC ±20%, ripple (P-P) 10% or less, Class 2 | |
Power supply | Current consumption (Max.) (mA) | Transmitter | 64 |
Receiver | 77 | ||
Protection circuit | Reverse current protection, short-circuit protection for each output, surge protection for each output | ||
Approved standards | EMC | EMS | IEC61496-1, EN61496-1, UL61496-1 |
EMI | EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA | ||
Safety | IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD) IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3) EN ISO13849-1:2015 (Category 4, PLe) UL508 UL1998 | ||
Environmental resistance | Enclosure rating | IP65/IP67 (IEC60529) | |
Overvoltage category | II | ||
Ambient light | Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less | ||
Operating ambient temperature | -10 to +55 °C (No freezing) | ||
Storage temperature | -25 to +60 °C (No freezing) | ||
Operating relative humidity | 15 to 85 % RH (No condensation) | ||
Storage relative humidity | 15 to 95 % RH | ||
Vibration resistance | 10 to 55 Hz, Double amplitude 0.7 mm, 20 sweeps in each of the X, Y, and Z directions | ||
Shock resistance | 100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions | ||
Material | Main unit case | Aluminium | |
Upper case/lower case | Nylon (GF 30%) | ||
Front cover | Polycarbonate, SUS304 | ||
Weight | Transmitter | 890 g | |
Receiver | 900 g | ||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 1.0 m. *2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms. *3 “All blocked” means the situation where the GL-R operates in optical synchronisation system and the transmitter and receiver is not synchronised (top and bottom beam axes are both blocked). In this situation, the response time is longer because the GL-R synchronises the transmitter and receiver fi rst and then determines the clear or blocked. *4 When the GL-R is used under surrounding air temperatures between 50 to 55°C, the Maximum load current should not exceed 350 mA. |