Mounting bracket LV-N11CN Keyence
Mounting bracket LV-N11CN Keyence

We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.

Keyence LV-N11CN

Manufacturer

Keyence

Country

Japan

Name

LV-N11CN

Type

Mounting bracket

Description

Amplifier, M8 Connector, Main unit, NPN

Stock availability:

On request

Price: On request

Order

Several positions are needed?

Send your request on email:

Worldwide delivery services:
fedex dhl ups
Ways of payment:
wire transfer paypal

Specifications LV-N11CN

If you need to buy Keyence LV-N11CN with quick delivery anywhere in the globe, then turn your attention to FAMAGA.

For more than 10 years, FAMAGA has not wholly provided customers with superior quality equipment Keyence, but also has a perfectly set up logistics chain. You can be sure that the order will appear anywhere in the planet as soon as possible. The customer doesn’t risk spending money on inadequate,unfit goods, thanks to the certified experts, who will learn all the specifics of the problem and help make the leading preference.

You get a faithful teammate for a long time through cooperating with FAMAGA. Our team are always ready to offer the most acceptable terms of purchase Keyence LV-N11CN for those who decide to become a constant consumer of the company. We are eager in setting up long-term and mutually beneficial cooperation with each customer. Wherefore, through collaborating with us, you get first-rate goods from world-class manufacturers of industrial materials at the fair price, with a guarantee from the manufacturer, furthermore full compliance with constitution and certification rules during shipment.

To get detailed information on questions of interest, connect with us. FAMAGA consultants will be delighted to guide. If you have a large order, then a list of the desirable items can be sent by e-mail [email protected].

Features LV-N11CN

Amplifier, M8 Connector, Main unit, NPN
Model LV-N11CN
Type 1 output
Output NPN
Cable/connector M8 connector
Main/Expansion unit Main unit
I/O Control outputs 1 output
External input 1 input
Monitor output None
Response time 80 µs (HIGH SPEED)/250 µs (FINE)/500 µs (TURBO)/1 ms (SUPER)/4 ms (ULTRA)/16 ms (MEGA) *1
Output selection LIGHT-ON/DARK-ON (switch-selectable)
Timer function Timer OFF/OFF-delay timer/ON-delay timer/One-shot timer, Timer duration selectable: 1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.
Control outputs NPN open collector 30 V, Residual voltage 1 V or less (Output current: 10 mA or less) / 2 V or less (Output current: 10 to 100 mA) (Stand-alone) 1 output max: 100 mA or less, 2 output total: 100 mA or less (Multiple connections) 1 output max: 20 mA or less
Monitor output -
External input Input time 2 ms (ON)/20 ms (OFF) or more*2
Multiple connections to expansion units Up to 17 units can be connected in total (two-output type is treated as two units)
Protection circuit Reverse polarity protection, Over-current protection, Surge absorber
Number of interference prevention units Connected to other than LV-S31: 0 for HIGH SPEED, 2 for FINE/TURBO/SUPER, 4 for ULTRA/MEGA, Connected to LV-S31: 2 for FINE, 4 for TURBO/SUPER/ULTRA/MEGA*3
Case size H 32.6 mm ? W 9.8 mm ? L 78.7 mm
Rating Power voltage 24 VDC (operating voltage 10 to 30 VDC (with ripple)), Ripple (P-P) 10 % or less, Class 2 or LPS
Power consumption Normal: 830 mW or less (at 30 V. 30 mA at 24 V, 56 mA or less at 12 V)*4 Eco on mode: 710 mW or less (at 30 V. 26 mA at 24 V, 48 mA or less at 12 V)*4 Eco Full mode: 550 mW or less (at 30 V. 21 mA at 24 V, 40 mA or less at 12 V) *5
Environmental resistance Ambient temperature -20 to +55 °C (No freezing)*6
Relative humidity 35 to 85 % RH (No condensation)
Vibration resistance 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions
Shock resistance 500 m/s2, 3 times in each of the X, Y, and Z directions
Material Cable PVC
Case Main unit and cover material: Polycarbonate
Weight Approx. 20 g
*1 80 µs cannot be selected when the LV-S31/S62/S63 is connected *2 Input time is 25 ms (ON)/25 ms (OFF) when external calibration time is selected. *3 These numbers double when 'DOUBLE' is selected. *4 Increases 30 mW (1 mA) for High Speed mode. *5 It increases by 15% when connected to the LV-NH100/NH110/NH300. It does not include the power consumption of the load. Power consumption when expansion units are connected is the total power consumption of each amplifier unit. Example: When one main unit (LV-N11N) is connected to 2 expansion units (LV-N12N) and they are used with LV-NH100 heads in HIGH SPEED mode. (1.15 ? 860 mW ? 1) + (1.15 ? 860 mW ? 2) = 2967 mW max. *6 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less for a unit. One or two more units connected: -20 °C to +55 °C , 3 to 10 more units connected: -20 °C to +50 °C, 11 to 16 more units connected: -20 °C to +45 °C. When using 2-outputs, one unit is counted as two units.