We are not the manufacturer, authorised distributor or authorised representative of the Keyence brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.
If you want to receive Keyence RD-50R with quick shipment anywhere in the earth, Canada, United States, Mexico, San Marino, Eswatini, Cyprus, South Korea, India, Israel, Togo, Slovenia, Qatar, Côte d\'Ivoire, Spain, Myanmar, Iceland, Saudi Arabia, Ethiopia, Tanzania, Guinea, Tunisia, Gabon, Guyana, Peru, Sri Lanka, China, Mauritania, Malaysia, Equatorial Guinea, Uganda, Estonia, United Arab Emirates, Rwanda, Ireland, Oman, Kuwait, Panama, Albania, Kiribati, Algeria, Malawi, Costa Rica, Andorra then turn your attention to FAMAGA.
For more than 10 years, FAMAGA has not particularly provided customers with superior quality equipment Keyence, but also has a perfectly established logistics bond. You can be confident that the order will turn up anywhere in the earth as soon as possible. The consumer doesn’t risk paying money on inadequate,unfit goods, thanks to the proficient professionals, who will review all the details of the problem and help make the finest option.
You get a faithful teammate for a long time through collaborating with FAMAGA. Our team members are always ready to give the most supportive terms of purchase Keyence RD-50R for those who decide to become a steady buyer of the company. We are open,attracted in setting up long-term and mutually productive collaboration with each customer. Consequently, through collaborating with us, you get superior quality equipment from prominent manufacturers of industrial materials at the acceptable charges, with a guarantee from the manufacturer, moreover full acquiescence with regulation and certification rules during delivery.
To get exact information on questions of interest, connect with us. FAMAGA experts will be delighted to support. If you have a massive order, then a list of the requested materials can be sent by e-mail [email protected].
Model | RD-50R | |
Measurement function | DC voltage measurement, DC current measurement | |
A/D converting system | Successive comparison | |
Measurement range | ±5 VDC, ±10 VDC, 4 to 20 mA DC (selectable) | |
Display range | -19999 to +39999 | |
Measurement accuracy | ±0.03 % of F.S. (at ±5 VDC range), ±0.03 % of F.S. (at ±10 VDC range) ±0.05 % of F.S. (at 4 to 20 mA DC range) | |
Input | Impedance | 1 M? (for voltage input), 350 ? (for current input) |
System | Single-ended | |
Number of inputs | 2 | |
Sampling rate | 2,000 times/second | |
Display speed | 20 times/second | |
Display power | 7-segment 3-colour LED (character height: 15.24 mm) | |
Over-range alarm | FFFF is displayed | |
Control input | Synchronous, Hold-reset, Auto-zero, External setting, NPN or non-voltage contact signal | |
Control input | Timing input | |
Hold reset input | ||
Auto-zero input | ||
External setting input | ||
Controloutput | Setting method | 4 steps x 8 programmable setups (selectable)*1 |
Signal | 5 x NPN (HH, HI, GO, LO, LL): 100 mA max. (40 V max.)*1 | |
Response time | 1 ms (when average number 1)*1 | |
OFF-delay time | 60 ms (ON/OFF selectable)*1 | |
Analogue output voltage | Output voltage | ±10 VDC |
Impedance | 100 ? | |
Response time | 1 ms (when average number 1)*2 | |
Interface | Data output and control input through RS-232C | |
Major functions | MDL, digital fi lter, auto-zero, offset, input, data processing (10 modes), tolerance limit storage (up to 8 sets), decimal point shift, error message display, etc. | |
Rating | Power voltage | 24 VDC ±10 %, Ripple (P-P) 10 % or less |
Current consumption | 270 mA or less | |
Environmental resistance | Ambient temperature | 0 to +50 °C |
Relative humidity | 35 to 85 % RH (No condensation) | |
Vibration resistance | 10 to 55 Hz, Double amplitude 1.5 mm, 2 hours in each of the X, Y, and Z directions | |
Weight | Approx. 700 g (excluding fi ttings) | |
*1 NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP output converter. *2 Requires 1.5 ms every second during self-compensation sequence to prevent temperature fl uctuations. |