'

We are not the manufacturer, authorised distributor or authorised representative of the LABOM brand in Canada. The private labels and part numbers shown on this website are the property of their respective owners.

LABOM – page 5

Selling any product from the catalog LABOM at good prices

Vendor code
Description
Price
PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 CV3110 A1 pressure sensor: piezoresistive for gauge pressure 059.1 nominal range: -1...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 6,000 unit: bar H11 output signal: 4...20 mA, rising characteristic (standard) 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) display module: multifunctional display with 5-position digital display and bar graph, pluggable M2 N10 switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T30 electrical connection: circular connector M12x1 (4 pin) K1085 design standard ADDITIONAL DESIGN: stainless steel Tag-plate with stainless steel wire marking see below W4022 W2002 CALIBRATION PROTOCOL: with 5 measuring points W2674 EAC-TR certification exemption statement DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with clamp connection see data sheet D5-026 3 process connection: per DIN 32676 model C (Tri-Clamp) for pipes per ASME BPE, DN 2" / PN 16 330 hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm HY A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered design temperature process +10...+140 °C L22 W4035 ADDITIONAL DESIGN: wetted parts electropolished W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts
On request
Get a price
PRESSURE TRANSMITTER PASCAL Ci4 for diaphragm seal operation, hygienic process connection bottom see data sheet D4-016-2 CI4110 nominal range: 0...4 bar, Turndown max. 100:1, overload limit 10 bar; sensor type piezoresistiv A1056 accuracy: <= 0.10% from adjusted measuring span (Lin./Hys./Rep., up to Turndown <=5:1 no changes) F2 parameterizing: see below -1...+3 bar H21 output signal: 4...20 mA with HART high-resolution graphic display with backlight intuitive 4-button operation, quick access to device data available languages (English, German), default setting English M21.1 Y1 material case: stainless steel mat. no. 1.4301/1.4305 (304/303) 2 material front cover: stainless steel, window non-splittering glass degree of protection: IP 65 / IP 67 T30 electrical connection: circular connector M12 x 1 (4 pin) K1085 design: standard X3 temperature compensation: active temperature compensation ATC marking: stainless steel Tag-plate, fixed with stainless steel wire, marking see below W4022 W2002 CALIBRATION PROTOCOL: with 5 measuring points W2674 EAC-TR certification exemption statement process connection: DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology design with clamp connection see data sheet D5-026 3 process connection: per DIN 32676 model C (Tri-Clamp) for pipes per ASME BPE, DN 2 1/2" / PN 16 430 hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered L23 T14 temperature, media: -10..+150 °C W4035 ADDITIONAL DESIGN: wetted parts electropolished W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts
On request
Get a price
MZ1100 COMBIBAR PRESSURE MEASURING SYSTEM B64 drawing no.: PD-WV-00178 BOURDON TUBE PRESSURE GAUGE: W2002 CALIBRATION PROTOCOL: with 5 measuring points PRESSURE TRANSMITTER PASCAL CV, for diaphragm seal operation, hygienic acc. to data sheet D4-017/22 CV3110 A1 pressure sensor: piezoresistive for gauge pressure 059 nominal range: 0...16 bar, overload limit 60 bar measuring range setting: turndown 5:1 accuracy: <= 0.15% of measuring span (linearity, hysteresis and repeatability) F80 measuring range: setting see below lower range value: - 1,000 upper range value: + 4,000 unit: bar H21 output signal: 4...20 mA with HART function module 0 setting damping: 0.0 sec. (standard) 0 setting alarm state: < 3.6 mA (standard) M1 display module: without screw cap closed, without window N10 switching module: without case: hygienic housing design with screw cap material: stainless steel degree of protection: IP 66 T30 electrical connection: circular connector M12x1 (4 pin) K1085 design standard process temperature 0...+125 °C, short term up to +140 °C, 1 h ADDITIONAL DESIGN: stainless steel Tag-plate with stainless steel wire marking see below W4022 W2674 EAC-TR certification exemption statement PRESSURE GAUGE DN 100 ECOnomic for food/pharmaceutical/biotechnology acc. to data sheet D2-028-5 BH52 00 case design: IP 65, process connection bottom A99 nominal range: see below -1 ... 4 bar overload protected: 1.3 times pointer: with micro adjusting device for zero-point correction CUSTOMER'S SPECIFICATION: scale: Zeta logo type plate: Labom documentation: Labom W5124 W2674 EAC-TR certification exemption statement DIAPHRAGM SEAL for food/pharmaceutical/biotechnology see data sheet D5-024-3 DL8 090 design: process connection per INGOLD hygienic design per EHEDG Doc.8 and ASME BPE SF3: surface roughness (wetted parts) - turned parts Ra <= 0.76 μm - diaphragm Ra <= 0.38 μm - weld seam Ra <= 0.76 μm HY D25 process connection: DN 25, hexagon union nut A/F 46, G 1 1/4" 46 insertion length: h = 46 mm E7 basic body material: stainless steel mat.-no. 1.4435 (316L), wetted part G7 diaphragm material: stainless steel mat.-no. 1.4435 (316L) H2 gasket: per EPDM -FDA A400 connection of meas. instrument directly welded system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered L23 DMB_729 T99 temperature, media: see below +10...+150°C W4035 ADDITIONAL DESIGN: wetted parts electropolished W1020 Components marked acc. to material inspection certificate per EN 10204-3.1, wetted parts
On request
Get a price
On request
Get a price
On request
Get a price
On request
Get a price

The site contains only a small part of the catalog items LABOM.

If you have not found the article you need, send a request to the mail [email protected] and we will definitely send you a commercial proposal.

You can buy products of other brands